Re: Wein cell battery I'll certainly look into the 675 type cells you suggested. Though the devloting-adapter for silver cells is probably more competitive, at least in the long run. I don't understand why a silver cell caused problems in your case - at least with a devolting-adapter or a re-adjustment of the meter, they should work perfectly as they deliver constant voltage (practically) throughout their lives. I've used the following 625 mercury cell alternatives successfully: Photomic FTn for Nikon F; 2 alkaline cells, meter readjusted, gives acceptable results throughout battery life. Exakamat meter prism for Exakta Varex; 1 alkaline cell, meter readjusted, gives acceptable results throughout battery life. Gossen Lunasix 3 hand held meter; 2 alkaline cells, meter readjusted, gives acceptable results throughout battery life. Leicaflex SL; 1 silver cell in devolting-adapter, meter not readjusted, accurate in all situations. TTL prism for Kiev 60; 3(?) silver cells with spacers, meter readjusted, gives accurate results throughout battery life. Chris Loffredo
|
|